1.
Nanoscale ; 16(14): 7123-7133, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38501609

RESUMO

Filters made of graphene oxide (GO) are promising for purification of water and selective sieving of specific ions; while some results indicate the ionic radius as the discriminating factor in the sieving efficiency, the exact mechanism of sieving is still under debate. Furthermore, most of the reported GO filters are planar coatings with a simple geometry and an area much smaller than commercial water filters. Here, we show selective transport of different ions across GO coatings deposited on standard hollow fiber filters with an area >10 times larger than typical filters reported. Thanks to the fabrication procedure, we obtained a uniform coating on such complex geometry with no cracks or holes. Monovalent ions like Na+ and K+ can be transported through these filters by applying a low electric voltage, while divalent ions are blocked. By combining transport and adsorption measurements with molecular dynamics simulations and spectroscopic characterization, we unravel the ion sieving mechanism and demonstrate that it is mainly due to the interactions of the ions with the carboxylate groups present on the GO surface at neutral pH.

2.
J Chem Phys ; 159(10)2023 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-37681700

RESUMO

A gold surface is functionalized by chemisorption of the enantiopure N,N'-bis-[2,2';5',2″]tert-thiophene-5-yl methylcyclohexane-1,2-diamine (2T3N), a chiral oligothiophene derivative, via overnight incubation in a 2T3N ethanol solution. The Au|2T3N interface is characterized by x-ray photoelectron circular dichroism and comparing x-ray photoemission spectroscopy and electro-desorption results. Charge transmission at the Au|2T3N| solution interface is characterized by recording the cyclic voltammetry of the Fe(III)/Fe(II) reversible redox couple, finding a charge transfer rate constant, k°, variation from 1 × 10-1 to 3.3 × 10-2 cm s-1, when comparing the bare Au and the Au|2T3N interfaces, respectively. The "anomalous" high value of k° found for the chiral Au|2T3N interface can be rationalized on the basis of the chiral-induced spin selectivity effect, as further proved by magnetic-conductive atomic force microscopy measurements at room temperature. A spin polarization of about 30% is found.

3.
Analyst ; 148(19): 4688-4697, 2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37602722

RESUMO

Two electrochemical sensors are proposed here for the first time for the fast screening of cannabinoids in Cannabis sativa L. plant material (inflorescences). The accurate control of cannabinoid content is important for discriminating between recreational, i.e. illegal, and fibre-type C. sativa samples, which differ mainly according to the amount of Δ9-tetrahydrocannabinol (Δ9-THC) and Δ9-tetrahydrocannabinolic acid (Δ9-THCA). Two screen printed electrodes obtained using different electrode materials were tested for the analysis of extracts from recreational and fibre-type C. sativa and their performance was compared with a consolidated method based on high-performance liquid chromatography (HPLC). The voltammetric responses recorded in the different samples reflected the compositional differences of the recreational and fibre-type extracts in accordance with the results of HPLC analyses. Moreover, the quantification of Δ9-THCA and the total cannabinoid content on the basis of the intensity of the peaks of the voltammograms was possible through a simple and fast electrochemical procedure.


Assuntos
Canabinoides , Cannabis , Canabinoides/análise , Cannabis/química , Dronabinol/análise , Extratos Vegetais/química
4.
Small ; 19(51): e2300163, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37144410

RESUMO

Hundreds of new electrochemical sensors are reported in literature every year. However, only a few of them makes it to the market. Manufacturability, or rather the lack of it, is the parameter that dictates if new sensing technologies will remain forever in the laboratory in which they are conceived. Inkjet printing is a low-cost and versatile technique that can facilitate the transfer of nanomaterial-based sensors to the market. Herein, an electroactive and self-assembling inkjet-printable ink based on protein-nanomaterial composites and exfoliated graphene is reported. The consensus tetratricopeptide proteins (CTPRs), used to formulate this ink, are engineered to template and coordinate electroactive metallic nanoclusters (NCs), and to self-assemble upon drying, forming stable films. The authors demonstrate that, by incorporating graphene in the ink formulation, it is possible to dramatically improve the electrocatalytic properties of the ink, obtaining an efficient hybrid material for hydrogen peroxide (H2 O2 ) detection. Using this bio-ink, the authors manufactured disposable and environmentally sustainable electrochemical paper-based analytical devices (ePADs) to detect H2 O2 , outperforming commercial screen-printed platforms. Furthermore, it is demonstrated that oxidoreductase enzymes can be included in the formulation, to fully inkjet-print enzymatic amperometric biosensors ready to use.


Assuntos
Técnicas Biossensoriais , Grafite , Nanoestruturas , Grafite/química , Tinta , Nanoestruturas/química , Técnicas Biossensoriais/métodos
5.
Talanta ; 253: 123969, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36191513

RESUMO

Pesticides play a key-role in the development of the agrifood sector allowing controlling pest growth and, thus, improving the production rates. Pesticides chemical stability is responsible of their persistency in environmental matrices leading to bioaccumulation in animal tissues and hazardous several effects on living organisms. The studies regarding long-term effects of pesticides exposure and their toxicity are still limited to few studies focusing on over-exposed populations, but no extensive dataset is currently available. Pesticides biomonitoring relies mainly on chromatographic techniques coupled with mass spectrometry, whose large-scale application is often limited by feasibility constraints (costs, time, etc.). On the contrary, chemical sensors allow rapid, in-situ screening. Several sensors were designed for the detection of pesticides in environmental matrices, but their application in biological fluids needs to be further explored. Aiming at contributing to the implementation of pesticides biomonitoring methods, we mapped the main gaps between screening and chromatographic methods. Our overview focuses on the recent advances (2016-2021) in analytical methods for the determination of commercial pesticides in human biological fluids and provides guidelines for their application.


Assuntos
Praguicidas , Humanos
6.
J Pharm Biomed Anal ; 206: 114346, 2021 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-34537622

RESUMO

Cannabis sativa L. is a plant known all over the world, due to its history, bioactivity and also social impact. It is chemically complex with an astonishing ability in the biosynthesis of many secondary metabolites belonging to different chemical classes. Among them, cannabinoids are the most investigated ones, given their pharmacological relevance. In order to monitor the composition of the plant material and ensure the efficacy and safety of its derived products, extraction and analysis of cannabinoids play a crucial role. In this context, in addition to a conventional separation method based on HPLC with UV/DAD detection, a new strategy based on a non-separation procedure, such as 13C-qNMR, may offer several advantages, such as reduced solvent consumption and simultaneous acquisition of the quali/quantitative data related to many analytes. In the light of all the above, the aim of this work is to compare the efficiency of the above-mentioned analytical techniques for the study of the main cannabinoids in different samples of cannabis inflorescences, belonging to fibre-type, recreational and medical varieties. The 13C-qNMR method here proposed for the first time for the quantification of both psychoactive and non-psychoactive cannabinoids in different cannabis varieties provided reliable results in comparison to the more common and consolidated HPLC technique.


Assuntos
Canabinoides , Cannabis , Alucinógenos , Canabinoides/análise , Cromatografia Líquida de Alta Pressão , Extratos Vegetais
7.
Sensors (Basel) ; 21(12)2021 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-34207281

RESUMO

Silica-based electrodes which permanently include a graphite/Au nanoparticles composite were tested for non-enzymatic detection of glucose and fructose. The composite material showed an effective electrocatalytic activity, to achieve the oxidation of the two analytes at quite low potential values and with good linearity. Reduced surface passivation was observed even in presence of organic species normally constituting real samples. Electrochemical responses were systematically recorded in cyclic voltammetry and differential pulse voltammetry by analysing 99 solutions containing glucose and fructose at different concentration values. The analysed samples consisted both in glucose and fructose aqueous solutions at pH 12 and in solutions of synthetic musts of red grapes, to test the feasibility of the approach in a real frame. Multivariate exploratory analyses of the electrochemical signals were performed using the Principal Component Analysis (PCA). This gave evidence of the effectiveness of the chemometric approach to study the electrochemical sensor responses. Thanks to PCA, it was possible to highlight the different contributions of glucose and fructose to the voltammetric signal, allowing their selective determination.


Assuntos
Grafite , Nanopartículas Metálicas , Técnicas Eletroquímicas , Eletrodos , Frutose , Glucose , Ouro , Limite de Detecção , Análise Multivariada , Dióxido de Silício
8.
J Pharm Biomed Anal ; 192: 113633, 2021 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-33039911

RESUMO

Cannabidiol (CBD) is a bioactive terpenophenolic compound isolated from Cannabis sativa L. It is known to possess several properties of pharmaceutical interest, such as antioxidant, anti-inflammatory, anti-microbial, neuroprotective and anti-convulsant, being it active as a multi-target compound. From a therapeutic point of view, CBD is most commonly used for seizure disorder in children. CBD is present in both medical and fiber-type C. sativa plants, but, unlike Δ9-tetrahydrocannabinol (THC), it is a non-psychoactive compound. Non-psychoactive or fiber-type C. sativa (also known as hemp) differs from the medical one, since it contains only low levels of THC and high levels of CBD and related non-psychoactive cannabinoids. In addition to medical Cannabis, which is used for many different therapeutic purposes, a great expansion of the market of hemp plant material and related products has been observed in recent years, due to its usage in many fields, including food, cosmetics and electronic cigarettes liquids (commonly known as e-liquids). In this view, this work is focused on recent advances on sample preparation strategies and analytical methods for the chemical analysis of CBD and related compounds in both C. sativa plant material, its derived products and biological samples. Since sample preparation is considered to be a crucial step in the development of reliable analytical methods for the determination of natural compounds in complex matrices, different extraction methods are discussed. As regards the analysis of CBD and related compounds, the application of both separation and non-separation methods is discussed in detail. The advantages, disadvantages and applicability of the different methodologies currently available are evaluated. The scientific interest in the development of portable devices for the reliable analysis of CBD in vegetable and biological samples is also highlighted.


Assuntos
Canabidiol , Canabinoides , Cannabis , Sistemas Eletrônicos de Liberação de Nicotina , Criança , Dronabinol , Humanos
9.
Analyst ; 146(2): 612-619, 2021 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-33185206

RESUMO

A glassy carbon electrode chemically modified with a carbon black coating is proposed here for the rapid and portable determination of cannabidiol (CBD) in a commercial Cannabis seed oil and in fibre-type Cannabis sativa L. leaves. The mechanism of CBD oxidation was studied in relation to simpler phenyl derivatives bearing the same electroactive group, namely resorcinol and 2-methylresorcinol. These molecules also allowed us to determine the best conditions for the electrochemical detection of CBD, as to the pH value and to the best solvent mixture to use. Carbon black was chosen among nanostructured carbon-based materials owing to its outstanding features as an electrode modifier for analyte detection. The performance of the modified electrode was determined by flow injection analyses of standard solutions of CBD, obtaining a linear correlation between the oxidation current and the analyte concentration; the sensor response is characterised by suitable repeatability and reproducibility. The analysis of commercial products by the standard addition method allowed us to ascertain the accuracy of the sensor for the detection of CBD in real samples.


Assuntos
Canabidiol/análise , Eletroquímica/instrumentação , Extratos Vegetais/química , Fuligem/química , Verduras/química , Canabidiol/química , Folhas de Planta/química , Água/química
10.
Sensors (Basel) ; 19(3)2019 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-30691171

RESUMO

A flexible electrode system entirely constituted by single-walled carbon nanotubes (SWCNTs) has been proposed as the sensor platform for ß-nicotinamide adenine dinucleotide (NADH) detection. The performance of the device, in terms of potential at which the electrochemical process takes place, significantly improves by electrochemical functionalization of the carbon-based material with a molecule possessing an o-hydroquinone residue, namely caffeic acid. Both the processes of SWCNT functionalization and NADH detection have been studied by combining electrochemical and spectroelectrochemical experiments, in order to achieve direct evidence of the electrode modification by the organic residues and to study the electrocatalytic activity of the resulting material in respect to functional groups present at the electrode/solution interface. Electrochemical measurements performed at the fixed potential of +0.30 V let us envision the possible use of the device as an amperometric sensor for NADH detection. Spectroelectrochemistry also demonstrates the effectiveness of the device in acting as a voltabsorptometric sensor for the detection of this same analyte by exploiting this different transduction mechanism, potentially less prone to the possible presence of interfering species.

11.
Anal Bioanal Chem ; 408(26): 7329-38, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27236311

RESUMO

Poly(3,4-ethylenedioxythiophene)-modified electrodes have been used for the estimation of the polyphenolic content and of the colour index of different samples of wines. Synthetic wine solutions, prepared with different amount of oenocyanins, have been analysed spectrophotometrically and electrochemically in order to find a correlation between the total polyphenolic content or colour index and the current peak. The regression curves obtained have been used as external calibration lines for the analysis of several commercial wines, ranging from white to dark red wines. In this way, a rapid estimation of the total polyphenolic content and of the colour index may be accomplished from a single voltammetric measurement. Furthermore, principal component analysis has also been used to evaluate the effect of total polyphenolic content and colour index on the whole voltammetric signals within a selected potential range, both for the synthetic solutions and for the commercial products. Graphical abstract Electrochemical sensors for the rapid determination of colour index and polyphenol content in wines.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes/química , Técnicas Eletroquímicas/métodos , Polímeros/química , Polifenóis/análise , Vinho/análise , Cor , Eletrodos , Análise de Componente Principal
12.
Anal Bioanal Chem ; 407(3): 983-90, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25326890

RESUMO

The control of the noble metal concentration is crucial in order to increase the efficiency of hydrometallurgic processes in mining and in the recovery of precious materials from electronic waste. The present study is devoted to the development of an effective procedure for the quantification of Au(III) species dissolved in aqueous solutions, similar real complex matrices included. In particular, a novel electrode system based on Ti has been studied. This electrode material is still poorly investigated in the framework of electroanalysis, despite its lack of sensitivity to common interfering species, such as oxygen; hence, the determination of metal species can be carried out without performing deaeration of the solution. In addition, the interfering effect due to the presence of other heavy metal ions, such as Ag, Fe and Pb, has been minimised by a proper choice of the conditions adopted for the amperometric measurements. Ti electrodes exhibit reproducible electrochemical responses, even in the presence of high concentration of organic fouling species typical of biosorption processes.

13.
Sensors (Basel) ; 13(4): 4571-80, 2013 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-23567525

RESUMO

n instrument for the automatic quantification of glycerol in grapes has been developed. We verify here that this analyte can be used as a benchmark of a serious disease affecting the grapevines, namely Botrytis cinerea. The core of the instrument is an amperometric biosensor consisting of a disposable screen printed electrode, generating the analytical signal thanks to a bi-enzymatic process involving glycerol dehydrogenase and diaphorase. The full automation of the analysis is realised by three micropumps and a microprocessor under control of a personal computer. The pumps allow the correct and constant dilution of the grape juice with a buffer solution also containing [Fe(CN)6]3- redox mediator and the injection of NAD+ cofactor when the baseline signal reaches a steady state; the instrument leads to automated reading of the analytical signal and the consequent data treatment. Although the analytical method is based on an amperometric technique that, owing to heavy matrix effects, usually requires an internal calibration, the analyses indicate that a unique external calibration is suitable for giving accurate responses for any grapes, both white and black ones.


Assuntos
Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Vitis/microbiologia , Automação , Botrytis , Eletroquímica , Glicerol/análise
15.
Anal Bioanal Chem ; 405(11): 3579-86, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23283286

RESUMO

A gold electrode partially coated by graphene multilayer is developed and tested with respect to high concentrations of hydrogen peroxide. The effective use of conventional electrode materials for the determination of such an analyte by anodic oxidation or cathodic reduction is prevented by the occurrence of adsorptions fouling the electrode surface. This prevents reliable and repeatable voltammetric curves for being recorded and serious problems arise in quantitative analysis via amperometry. The gold-graphene electrode is shown to be effective in quantitative evaluation, by cathodic reduction, of hydrogen peroxide at concentration levels that are of interest in an industrial. Acid, neutral, and basic pH values have been tested through correct adjustment of a Britton Robinson buffer. The experiments have been performed both by cyclic voltammetry and with amperometry at constant potential in unstirred solution. The latter technique has been employed in drawing a calibration linear plot. In particular, the performances of the developed electrode system have been compared with those of both pure gold and pure graphene electrode materials. The bi-component electrode was more sensitive; co-catalytic action by the combination of the two components is hypothesised. The system is stable over many potential cycles, as checked by surface-enhanced Raman spectra recorded over time.

16.
Artif DNA PNA XNA ; 3(2): 80-7, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22772036

RESUMO

A homothymine PNA decamer bearing four lysine residues has been synthesized as a probe for the development of amperometric sensors. On one hand, the four amino groups introduced make this derivative nine times more soluble than the corresponding homothymine PNA decamer and, on the other hand, allow the stable anchoring of this molecule on Au nanostructured surface through the terminal -NH 2 moieties. In particular, XPS and electrochemical investigations performed with hexylamine, as a model molecule, indicate that the stable deposition of primary amine derivatives on such a nanostructured surface is possible and involves the free electron doublet on the nitrogen atom. This finding indicates that this PNA derivative is suitable to act as the probe molecule for the development of amperometric sensors. Thanks to the molecular probe chosen and to the use of a nanostructured surface as the substrate for the sensor assembly, the device proposed makes possible the selective recognition of the target oligonucleotide sequence with very high sensitivity.


Assuntos
Técnicas Biossensoriais/métodos , Eletroquímica/métodos , Lisina/química , Ácidos Nucleicos Peptídicos/química , Sequência de Bases , Eletrodos , Ouro/química , Nanopartículas Metálicas/química , Ácidos Nucleicos Peptídicos/genética , Solubilidade
17.
Chem Commun (Camb) ; (12): 1640-2, 2005 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-15770286

RESUMO

The incorporation of thioether groups in the structure of a Mn12 single-molecule magnet, [Mn12(O12)(L)16(H2O)4] with L = 4-(methylthio)benzoate, is a successful route to the deposition of well-separated clusters on native gold surfaces and to the addressing of individual molecules by scanning tunnelling microscopy.

18.
J Phys Chem B ; 109(41): 19397-402, 2005 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-16853505

RESUMO

In this article the adsorption of 3-methylthiophene on planar and nanoparticle Au surfaces is investigated. The resulting systems are compared with a benchmark system based on 1-decanethiol. The characterization data collected evidence the formation of a packed 3-methylthiophene SAM on the planar surface. In particular, spectroscopic investigations suggest that 3-methylthiophene aromatic system is not adsorbed on the surface through the pi-electron system but rather through the S atom alone. On the other hand, the behavior of 3-methylthiophene on nanoparticle surfaces is notably different from that of the alkanethiol. Only a limited fraction of the surface of Au nanoparticles results to be actually coated after purification; this notwithstanding, the nanoparticle growth seems to be strongly influenced by the presence of such a labile encapsulating agent.

19.
Ann Chim ; 94(3): 165-76, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15206838

RESUMO

The static dielectric constant of the [DMF(1) + ME(2) + DME(3)] ternary mixtures was measured as a function of temperature (25 < or = t/degrees C < or = 80) and composition, over the whole mole fraction range 0 < or = chi,chi2,chi3 < or = 1. The experimental values were processed by an empirical equation accounting for the dependence epsilon = epsilon(T, phi(i)), where phi(t) is the volume fraction of the components. A comparison between calculated and experimental data shows that this fitting relationship can be effectively employed to predict epsilon values in correspondence to experimental data gaps. Starting from the experimental measurements, some derived quantities such as molar polarisation (P), and excess counterpart (PE) were obtained. Both the excess properties, epsilonE and PE, take values partly positive and partly negative under all experimental conditions. The values of the excess quantities are indicative of the presence of specific interactions among different components in the mixtures.


Assuntos
Modelos Químicos , Solventes/química , Eletroquímica , Temperatura
20.
Chemphyschem ; 4(11): 1216-25, 2003 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-14653001

RESUMO

The 3,3''',3'''''-tris(butylsulfanyl)- 2,2':5',2'':5'',2''',5''',2'''':5'''',2'''''-sexithiophene 1 was investigated through spectroscopic (NMR, EPR, UV/Vis-NIR), electrochemical, spectroelectrochemical and theoretical (DFT) studies. The charged species obtained upon its oxidation and reduction were characterised, showing that 1 can exist in at least five different oxidation states, that is, a neutral species, a radical cation, a dication, a radical anion, and a dianion. The long term stability of the radical cation 1+. was evidenced by the 1H NMR study in the presence of small quantities of trifluoroacetic acid (TFA). This approach allowed a comparison of the relative broadening of proton signals of 1, induced by the electron exchange process with traces of radical cation 1+., and the hfc (hyperfine coupling) constants obtained from the EPR study and DFT calculations. In the radical cation, all of the heterocyclic sulphur atoms are not significantly involved in the delocalisation of the unpaired electron, whereas the opposite holds for the radical anion. Time-dependent DFT calculations reproduced well the wavelengths of the optical transitions observed in the spectroelectrochemical experiments for all the five oxidation states and support the formation of the dianion 1(2-).


Assuntos
Radicais Livres/química , Fosfatidiletanolaminas/química , Polímeros/química , Tiofenos/química , Ânions , Hidrocarbonetos Aromáticos com Pontes/química , Cátions , Eletroquímica/métodos , Elétrons , Espectroscopia de Ressonância Magnética , Modelos Moleculares , Modelos Teóricos , Oxirredução , Análise Espectral/métodos , Enxofre/química , Fatores de Tempo , Ácido Trifluoracético/química
SELEÇÃO DE REFERÊNCIAS